GOF Cable
A-V(ZN)11Y 4G50-125, OM3, Mini-Breakout 5.6mm
A-V(ZN)11Y 4G50/125, OM3, Mini-Breakout 5.6mm
A-V(ZN)11Y 4G50/125, OM3, Mini-Breakout 5.6mm
Application | |
This cable is suitable for harsh environment industrial application Cable for flexible applications indoor and outdoor | |
| |
Standard | |
IEC 60793-2-10 Cat.A1a.2 | Multi-mode fiber
|
IEC 60794-2 | In-door cable
|
IEC 60794-1-2 | Cable type test |
Structure | |
Central strength element | |
Material | FRP |
Diameter | 0.5 ± 0.15 mm |
Fiber | |
Core diameter | 50 ± 2.5um |
Cladding diameter | 125 ± 1 um |
Coating diameter | 245 ± 10 um |
Buffer | |
Material | TPE-E |
Diameter | 0.9 ± 0.05 mm |
Color | Blue, Orange, Green, Brown |
Reinforce element | |
Aramide yarn | |
Jacket | |
Material | TPE-U |
Diameter | 5.6 ± 0.3 mm |
Color | Black |
Printing | A-V(ZN)11Y 4G50/125 xxxxM |
| |
Optics Performance | |
Attenuation | < 3.2 dB/km @ 850nm |
| < 1.0 dB/km @ 1300nm |
Bandwidth | > 1500 MHz·km @ 850nm |
| > 500 MHz·km @ 1300nm |
NA | 0.200 ± 0.015 |
| |
Mechanical Parameter | |
Tensile strength | IEC 60794-1-2 E1 |
| > 1000N Long term |
| > 2000N Short term |
Bending radius | IEC 60794-1-2 E11 |
| > 90mm Long term |
| > 45mm Short term |
Crush | IEC 60794-1-2 E3 |
| >4000 N/dm |
Torsion | IEC 60794-1-2 E7 |
| Cycles: 1000 times |
| Length: 1000 mm |
| Angle: + 1440 degree |
Repeat bending | IEC 60794-1-2 E6 |
| Radius: 50 mm |
| Weight: 2kg |
| Cycles: 20000 |
Drag Chain | Bending Radius 80 mm |
| Travel speed 15 m/s |
| Acceleration 10 m/s² |
| Cycles 10 mil. |
| |
Climate Properties | |
Storage and transportation | -40 ℃ to + 70 ℃ |
During installation | -40 ℃ to + 85 ℃ |
Operation | -40 ℃ to + 70 ℃ |
| |
Flame Characteristic | |
Fire resist and halogen free | |